What the camera found, and what puts it right
Price your flue repair
Tell us what the report flagged and what heats the fireplace now.
Reading the flue findings
Most failed Level 2 reports start inside the flue, not from the brick you can see. Clay tiles crack from heat and from ground movement; Southern California chimneys took both the 1987 Whittier Narrows shaking and the 1994 quake. Mortar between tiles washes out and leaves gaps. Some flues were never lined at all. And many older inserts were fitted with a short connector that pushes exhaust into the old smoke chamber instead of carrying it to the top.
Each of those breaks the same rule: exhaust has to travel in a sound, sealed passage all the way out. The report names which one you have, with the camera still beside it.
- Cracked or split clay tiles
- Open mortar joints between tiles
- No liner in the chimney at all
- An insert vent or liner that stops short of the top
- A liner the wrong size for the unit on it
The usual fix: a new liner
For almost every flue finding, the repair is a stainless steel liner run from the appliance to the top, sized to the fireplace or insert it serves, often with insulation around it. The old clay becomes a sleeve the new pipe sits in. If you are keeping an open wood fireplace, the liner is sized to the opening. If an insert is going in, or already there, it is sized to the insert's collar, and that is often the moment to choose the insert too.
Liners are quoted in writing after we measure, because height, diameter, bends and insulation change the figure from one chimney to the next. The quote names each part so you can see what you are paying for.
Fixes at the top and the roof
A failed report often lists the top as well: a cap gone or rusted through in salty air, a leak where the chimney meets the roof, a wide chimney with no diverter behind it. These carry prices on this site and are listed below. Crown work, chase covers, damper repairs and flashing on its own are quoted in writing after we see them.
When a gas insert is the simpler answer, for example where an old wood fireplace would need a costly reline and the owner only wants heat, we price that as an option beside the liner.
Flue and roof fix prices
Fixes that carry a published price on this site. A rain hood is quoted after we measure. Liners, crowns, chase covers and dampers are quoted in writing.
- Swapping the open fire for a sealed gas heater
- $2,950 to $5,900
- Stopping water at the stack
- $590 to $3,550
- Diverter on the high side of the chimney
- $470 to $1,065
- Diverter and new roof metal together
- $710 to $1,750
- Camera recheck after the repair
- $410
Every repair is quoted in writing before work starts, with the parts named on each line.
Flue repair questions
Can a cracked flue be repaired without a liner?
Sometimes a few open joints can be resealed, but most cracked or split tiles are dealt with by relining, which puts a sound new passage inside the old one.
My insert passed when it went in. Why did it fail now?
Older installs often used a short connector into the smoke chamber. Current practice runs the vent or liner to the top, and an inspector will flag one that stops short.
Is it cheaper to switch to a gas insert than to reline for wood?
It can be. A gas insert still needs its vent run to the top, but those vents are smaller and the job is more predictable. We price both options side by side when either would fix the finding.
Do you recheck the flue after the repair?
Yes, on request. A second camera pass once the repair is done gives you after stills to set beside the before ones, which helps when a buyer or an insurer asks for proof.
Why are liners not on the price list?
Two chimneys rarely need the same liner. Height, diameter, bends and insulation change the figure, so we measure and quote it in writing.
Holding a failed report?
Send us what it flagged through the contact page, and we will come out, measure the flue and price the fix line by line.
Call (323) 524-3550